LED bulkhead lights are one of the most widely specified fittings in commercial and residential electrical installations. Robust, energy-efficient, and available with integral emergency and PIR variants, they suit stairwells, corridors, car parks, garages, external walls, plant rooms, and utility spaces where durability and low running costs matter more than aesthetics.
This guide covers bulkhead light types, IP and IK ratings, wiring configurations, emergency gear, PIR operation, and the installation requirements UK electricians need to meet under BS 7671.
A bulkhead light is a self-contained luminaire mounted directly to a wall or ceiling surface, with a robust housing — typically polycarbonate (PC), ABS, or die-cast aluminium — that encloses the lamp and gear. The housing is sealed against the ingress of dust and water, making bulkheads suitable for locations where a standard open or semi-recessed fitting would fail.
Traditional bulkheads used 2D, PL, or circular fluorescent lamps. Modern versions are almost universally LED, with the light source integrated into the fitting or replaceable as an LED module. Integrated LED bulkheads offer 30,000–50,000 hour lamp life, typically 3,000–4,000K colour temperature for utility spaces, and driver efficiencies of 85–92%.
The IP (Ingress Protection) code is defined in BS EN 60529 and consists of two digits:
For bulkhead lights:
| IP Rating | Suitable Locations |
|---|---|
| IP20 | Indoor only, dry environments — rarely specified for bulkheads |
| IP44 | Indoor damp locations, domestic utility rooms, protected external soffits |
| IP54 | Light rain exposure, exposed corridors, industrial interiors |
| IP65 | Direct rain, car parks, external walls, plant rooms — the standard external specification |
| IP66 | Powerful jets, wash-down environments |
| IP67/IP68 | Temporary or sustained immersion — specialist applications |
For bathroom and shower zone compliance see the APM guide to IP ratings and bathroom zones. Bulkheads in Zone 1 require a minimum IP45 rating; Zone 2 requires IP44.
The IK code (BS EN 62262) measures resistance to mechanical impact in joules:
Always check the IK rating alongside IP. A fitting can be IP65 but have an IK06 rating — fine for a sheltered external wall, but not suitable for a multi-storey car park column where impact from vehicles or trolleys is possible.
Single-circuit fitting connected to the mains supply, switching on and off with the circuit. Available with:
Emergency bulkheads incorporate a battery pack (NiMH or Li-ion) that maintains illumination for a minimum of 3 hours if the mains supply fails. Two types:
Emergency bulkheads also feature:
For full emergency lighting requirements see the APM guide to emergency lighting BS 5266.
Most LED bulkheads are wired as simple switch-fused spurs or on a lighting circuit. The fitting has a terminal block or flying leads accepting the supply cable.
Supply (Live from switch) → L terminal Neutral → N terminal CPC (Earth) → E/PE terminal
Cable entry is via a knockout or gland plate. Always use a suitably rated cable gland to maintain the IP rating — an unsealed entry point will degrade the IP65 rating to IP20.
Cable sizing: typically 1.0mm² or 1.5mm² T&E for a lighting spur. Where the bulkhead is on a ring or radial lighting circuit, use the circuit cable sizing — most domestic and light commercial lighting circuits use 1.0mm² or 1.5mm² 6242Y.
An integral PIR bulkhead switches the LED load internally — no external switch is required, although an override or isolation switch is good practice. Wire as standard (L/N/E) and the PIR handles the switching.
Where a separate wall-mounted PIR is used to switch multiple bulkheads:
Supply → Permanent Live → PIR → Switched Live → Bulkhead L terminal Supply → Neutral → Bulkhead N terminal
PIR range, dwell time, and lux threshold are adjustable via trim pots on most units. Set lux threshold to prevent unnecessary activation in lit conditions; set dwell to minimum required (typically 30 seconds–5 minutes depending on application).
Emergency bulkheads require a permanent live supply to charge the battery, plus the switched live for normal illumination (maintained type) or as an inhibit input (non-maintained type):
Permanent Live → Battery charge input (often marked CL or PL) Switched Live → Mains supply input (for maintained: operates fitting; for non-maintained: inhibit) Neutral → N terminal Earth → E terminal
On non-maintained fittings: when the switched live is present (mains on, switch closed), the battery charges and the lamp is off. When the switched live is lost (mains failure), the battery activates the lamp.
Always check the wiring diagram in the fitting's data sheet — the terminal labelling varies between manufacturers.
Bulkheads on a lighting circuit are protected by the circuit breaker (typically 6A Type B for domestic lighting). Where a bulkhead is on a spur from a ring circuit:
For external and commercial bulkheads, a 6A or 10A Type B MCB on a dedicated lighting circuit is standard. Ensure the circuit is RCD-protected — required under Amendment 3 of BS 7671:2018 for all socket and lighting circuits in most premises types.
See the APM guides to cable sizing and current-carrying capacity and
All Class I bulkhead luminaires (metal housing or metal gland plate) must be earthed. The CPC must be continuous and correctly sized — for a 1.5mm² cable this is a 1.5mm² CPC within the T&E.
Class II (double-insulated) fittings, marked with the double-insulation symbol (□ within □), do not require a protective earth. However, the circuit earth must still be present at the accessory as the IP rating of the gland is critical to the fitting's safety.
Supplementary bonding in bathrooms: where a Class I bulkhead is installed in a bathroom zone, it must be included in the supplementary equipotential bonding or the circuit must be RCD-protected (≤30mA). See the APM guide to earth bonding and equipotential bonding.
In England and Wales, replacing a light fitting like-for-like (same position, same circuit) is generally notifiable only if in a special location (bathroom, kitchen). Installing a new circuit, adding a consumer unit circuit, or extending wiring into a bathroom requires notification under Part P. See the APM guide to Building Regulations Part P for full scope rules.
Bulkheads are typically fixed via a rear entry back plate or central fixing boss. Use appropriate fixings for the substrate:
Escape route luminaires should be mounted at 2–2.5m above finished floor level for maximum illuminated coverage, in line with BS 5266 recommendations. External security bulkheads are typically at 2.4–3m for coverage and vandal deterrence.
BS 5266-1 requires:
Self-test bulkheads (most modern units) perform monthly and annual tests automatically and flag faults via a red/green LED on the fitting. Central monitoring systems (via DALI or addressable protocols) aggregate results across a building.
Integrated LED bulkheads are not field-repairable in the traditional sense — the LED module is not a user-replaceable part on most fittings. At end-of-life (typically 30,000–50,000 hours ≈ 10–15 years at 8 hours/day), the full fitting is replaced.
Some premium bulkheads use LED modules on a standardised format (e.g. Zhaga Book 3 or Book 12) allowing module replacement. Emergency battery packs, however, are field-replaceable on most fittings — the battery cartridge clips out without tools, important for maintaining emergency compliance over the fitting's life (batteries typically last 4–5 years before capacity degrades below 80%).
| Fitting Size | Typical Wattage | Lumen Output | Application |
|---|---|---|---|
| Small (100–150mm) | 5–8W | 400–700lm | Domestic porch, utility room |
| Medium (180–200mm) | 8–15W | 700–1400lm | Stairwell, garage, corridor |
| Large (240–300mm) | 15–25W | 1400–2500lm | Car park, industrial corridor, large external |
| High-output (320mm+) | 25–50W | 2500–5000lm | Loading bay, warehouse, plant room |
LED bulkhead lights are the workhorse luminaire for any UK electrical installation requiring durable, weatherproof, long-life lighting in utility, commercial, or external locations. Key decisions are IP rating (IP65 for external/car park), IK rating (IK08–IK10 for impact-risk areas), emergency type (maintained vs non-maintained based on use pattern), and wiring configuration (permanent live essential for emergency battery charging).
Related APM guides: Emergency Lighting BS 5266 | IP Ratings Explained | RCDs and RCBOs | Cable Sizing Guide | FCUs and Fused Spurs | Part P Regulations