Smoke alarms and carbon monoxide (CO) detectors are legal requirements in UK residential properties — and choosing the right type, positioning them correctly, and replacing them on schedule is essential for both compliance and life safety. This guide covers what UK regulations require, the difference between optical, ionisation, and thermoptek detection, and which products to stock for domestic and light commercial installations.
The Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022 (England) require landlords to install smoke alarms on every storey used as living accommodation, and CO alarms in any room with a fixed combustion appliance (gas boiler, log burner, open fire). These rules apply to all private rented properties since 1 October 2022. Scotland, Wales, and Northern Ireland have separate but similar legislation.
For new builds and full renovations, Approved Document B (fire safety) and Approved Document J (combustion appliances) set interlinked mains-powered alarm requirements. BS 5839-6 provides the detailed specification for domestic fire alarm systems — installers working on private rental or new-build properties need to be familiar with Grade D (mains with battery backup) and Grade F (battery-only) systems.
Not all smoke alarms detect the same type of fire. Choosing the right sensor technology for the room matters:
CO is colourless and odourless — a detector is the only way to know if levels are rising. CO alarms are required in any room with a gas, oil, or solid fuel appliance. The EN 50291 standard governs CO alarm performance in the UK.
Key installation rules:
For rental properties and refurbishments, battery alarms are common where retrofitting mains wiring is impractical. 10-year sealed battery alarms are the current best practice — they eliminate the risk of tenants removing batteries when the low-battery chirp activates, and they last the full expected life of the alarm before replacement.
For new build and full renovation projects, mains-powered with battery backup (Grade D to BS 5839-6) is the standard. Interlinked alarms — where one detector triggering sounds all alarms in the property — are increasingly common even in battery systems via radio interlinking (no wiring required between units).
Standard positioning for smoke alarms:
In practice, most installers fit a smoke alarm in the hallway and landing, and a heat alarm in the kitchen. Properties with solid fuel appliances also need a CO alarm in any room with a stove or open fire.
Interlinked alarms sound all units when any one triggers — essential in larger properties and required under BS 5839-6 Category LD2 or LD1 systems. Radio interlink eliminates the need for hardwiring between units, making it practical for retrofit installations. The FireAngel ST-632 supports radio interlinking with compatible FireAngel devices.
Smoke alarms and CO detectors have a defined service life:
Landlords and housing managers should log installation dates and set replacement reminders. Many electricians now include alarm checks in annual inspection visits.

The FireAngel ST-632 uses Thermoptek dual-sensor technology to minimise nuisance alarms while maintaining fast detection. Sealed 10-year lithium battery — no battery changes required. Radio interlink compatible (FireAngel RF system). The most specified battery smoke alarm for UK domestic properties. Suitable for hallways, landings, and living rooms.

The Arctic Hayes SleepSafe COA10 meets BS EN 50291 and the 2022 CO Alarm Regulations. Sealed 10-year battery — no annual battery replacement. Digital display shows CO concentration in parts per million (ppm). Suitable for use in rooms with gas boilers, gas fires, and solid fuel appliances. Compact wall or shelf-mounted design.

FireAngel's 10-year CO detector with sealed battery and end-of-life indicator. Electrochemical CO sensor rated to BS EN 50291. Suitable for installation near gas boilers, cookers, and heating appliances. Tested and approved to UK and EU standards. The Fs1326-T provides a step up in reliability from entry-level CO alarms for landlords requiring higher-spec protection.

The Aico Ei146e is a Grade D, Category LD3 optical smoke alarm for new build and renovation projects. 230V mains powered with rechargeable lithium backup battery — no alkaline battery maintenance required. Interlinks with the full Aico Ei100 series via hardwire and radio. Optical detection suited to living rooms and bedrooms. Complies with BS 5839-6 for UK domestic installations.
A simple guide for common situations:
UK regulations now require smoke alarms on every habitable storey and CO alarms in any room with a combustion appliance. 10-year sealed battery models like the FireAngel ST-632 and Arctic Hayes COA10 are the most practical choice for rental retrofits — no battery maintenance risk. For new build and full renovation, mains-powered interlinked alarms to BS 5839-6 Grade D are the correct specification. APM stocks a range of smoke, CO, heat, and combination alarms from FireAngel, Aico, Arctic Hayes, and Kidde.
Browse our full range of smoke and CO alarms or explore our safety products at APM Electricals.