Wet underfloor heating distributes low-temperature hot water through a network of loops embedded in or laid on a floor structure, heating the room from below. It is increasingly standard in new builds and high-specification refurbishments — and increasingly expected by clients having a bathroom or kitchen retiled. This guide covers the wet UFH components stocked at APM: Henco press-fit fittings for 16mm and 26mm pipe, the Emmeti pump assembly, and Novatherm tile backer board.
A wet UFH system consists of four main elements:
Henco is a Belgian manufacturer of multilayer composite pipe and press-fit fittings specifically designed for underfloor heating and plumbing. The 16mm range covers manifold connections, loop-to-primary transitions, and repair joints — the fittings you need when connecting or repairing a UFH loop.
26mm Henco pipe and fittings are used for the primary supply and return pipework connecting the boiler to the UFH manifold — the same function that 22mm copper serves in a conventional heating system, but in MLCP for lower heat loss and easier routing.
The pump assembly is the heart of a wet UFH system — it circulates water around the loops and blends the boiler flow temperature down to the correct UFH supply temperature. The Emmeti assembly combines three components in a pre-assembled unit:
This is a pre-assembled unit — the pump and TMV arrive already configured and ready to connect between the boiler primary circuit and the manifold. It significantly reduces installation time compared to assembling components separately.
Novatherm is a rigid thermal insulation board used as a tile backer in wet room and tiled floor applications, including directly over wet UFH screed. Its purpose in a UFH installation is twofold:
BS EN 1264 sets the maximum UFH floor surface temperature at 29°C for occupied areas (9°C above normal room temperature). This translates to a supply water temperature of approximately 35–45°C depending on the floor covering — lower for thick carpet or timber, higher for tile or stone. The Emmeti TMV assembly is set to maintain this blend automatically.
Standard loop spacing for domestic UFH is 150–200mm centres for a screed system and 100–150mm for a low-profile dry system. Closer spacing increases heat output but requires more pipe per m². 16mm pipe at 150mm centres in a standard screed delivers approximately 60–80W/m² at 40°C flow temperature — sufficient for well-insulated modern construction.
UFH systems must be filled, pressure tested, and flushed before the manifold actuators are fitted and the controls are commissioned. Pressure test at 6 bar for 30 minutes with no drop before pouring screed or closing the floor. Do not operate the system at full boiler temperature during the first 28 days — most screeds require a gradual temperature rise to cure properly and prevent cracking.
| Component | Product | Price |
|---|---|---|
| 16mm loop to manifold (½" BSP) | Henco 16mm × ½" Straight Female Iron Adaptor | |
| 16mm loop to 15mm copper | Henco 16mm × 15mm Press-Fit to Copper Compression | |
| 16mm loop repair | Henco 16mm Repair Coupling | |
| 26mm primary to boiler copper (22mm) | Henco 26mm × 22mm Straight Coupling to Copper | |
| Pump + TMV assembly | Emmeti T3 3W TMV with WILO Pump | |
| Tile backer board (per sheet, 0.72m²) | Novatherm 1200×600×6mm |
All UFH components are in stock for same-day collection at our Acton trade counter. Fitting out a development or commercial UFH installation? Call ahead to check quantities.