A fused connection unit (FCU) — also called a fused spur or fused outlet — is a fixed, fused point of connection used to supply an appliance directly from the ring final circuit or a dedicated radial without using a plug and socket. FCUs are standard on cooker hoods, extractor fans, bathroom heaters, outdoor light circuits, and immersion heater feeds. They provide overcurrent protection via a BS 1362 cartridge fuse while giving a permanent, tidy termination point directly at the appliance. This guide covers when and why to use an FCU, the main types available, fuse selection, wiring method, and the relevant requirements under BS 7671.
BS 7671 permits a fused spur to be taken from any point on a ring final circuit, or as the termination of a dedicated radial, provided the spur feeds only one item of fixed equipment and is protected by a fuse not exceeding 13A. An FCU is the correct choice when:
FCUs may not be used to supply socket outlets or other FCUs downstream. Each FCU feeds one piece of fixed equipment. Where multiple appliances need supply from a single spur, a junction box or a dedicated sub-circuit is required instead.
The majority of FCUs installed by UK electricians are switched. A switched FCU incorporates a double-pole (DP) switch that disconnects both line and neutral when open — providing local isolation in compliance with BS 7671 Regulation 537.2.1.1. This is essential for any appliance that the user or an engineer may need to isolate safely without going to the consumer unit.
Unswitched FCUs are occasionally specified where the appliance has its own integral switch and local isolation is controlled elsewhere. They are more common in commercial fit-outs and on permanent supplies to alarms, ventilation, and CCTV where the FCU is a fusing point only.
For domestic kitchens and bathrooms, a switched FCU is the standard choice. Many models include an illuminated rocker or neon indicator so it is clear whether the supply is live — useful on cooker hoods where the switch is often above or behind the unit.
White plastic FCUs are standard for internal installations: kitchens, utility rooms, airing cupboards, loft spaces, and any surface where a wiring accessory plate is appropriate. They mount on a standard single-gang back box (25mm or 35mm depth) and match existing socket and switch plates.
Metal clad FCUs are specified for:
Metal clad FCUs with a flex outlet are particularly common behind cooker hoods and bathroom shaver or heater feeds where a short run of flexible cord runs directly into the FCU terminal. The flex grip (often a supplied rubber grommet) secures the cord and prevents chafing against the metal knockouts.
The FCU's cartridge fuse should be rated as close to the running current of the connected appliance as possible without nuisance blowing. The three most common ratings are:
Most FCUs are supplied with a 13A fuse fitted. Always replace this with the correct rating for the appliance before commissioning. A 13A fuse in a cooker hood FCU provides virtually no additional protection — the 3A fuse is needed to protect the cord and the appliance's internal wiring. BS 1362 fuses are available as replacement packs or are often included with the FCU.
A spur from a ring final circuit is taken from a socket outlet, a junction box, or a junction in the back of an existing socket. The supply to the FCU is wired into the "FEED" or "MAINS" terminals, and the "LOAD" or "SWITCHED LIVE" terminals connect to the appliance. Standard wiring practice:
For FCUs with a flex outlet, the appliance flex connects to the LOAD side terminals and exits through the flex outlet knock-out with the grip tightened. The FCU then terminates directly on its own surface-mounted back box adjacent to the appliance.
BS 7671 Section 701 restricts electrical equipment in bathroom zones. Socket outlets are not permitted in zones 0, 1, or 2. However, shaver supply units and SELV switches for extractor fans and heaters may be installed in Zone 2 (and Zone 1 with appropriate IP rating) provided the equipment has the correct IP rating and the installation meets 701.512.2.
An FCU supplying a bathroom extractor fan or heated towel rail must be located outside the bathroom zones if possible, or at minimum in Zone 2 with an IP44 or higher rating. Metal clad FCUs or appropriately rated white plastic FCUs with splash-proof ratings are available for these applications. A switched FCU outside the bathroom zone with cable routed to the extractor is the preferred approach in most domestic installations.
The standard approach for a cooker hood connection in domestic kitchens:
If the cooker hood is on its own dedicated radial (uncommon in domestic), the circuit breaker in the consumer unit provides the primary overcurrent protection and the FCU fuse still provides close protection for the appliance and its flex.
£5.99
The trade standard white plastic switched FCU from MK. Double-pole switch with illuminated neon indicator — essential for confirming live status on cooker hood and extractor installations. Accepts BS 1362 cartridge fuses 3A–13A. Mounts on a standard single-gang 25mm back box. Classic white finish suits most domestic kitchens.
£12.99
Screwless matt black FCU with DP switch — designed for modern kitchen and utility room schemes where black is the specified finish. Slim-profile faceplate with tool-free cover removal for fuse replacement. Takes BS 1362 fuses. Matches Knightsbridge's screwless black socket and switch range for a co-ordinated finish.
£8.80
Metal clad switched FCU with integral flex outlet — the correct choice for cooker hoods where the appliance flex connects directly at the FCU, garages, outbuildings, and surface-wired industrial locations. Supplied with rubber flex grip insert. IP-rated enclosure. Takes BS 1362 fuses. Compatible with standard single-gang surface metal boxes.
£6.40
Budget-friendly metal clad switched FCU from AXIOM — strong option for outbuildings, garages, and commercial applications. DP switch, BS 1362 fuse carrier, and robust metal plate. A cost-effective alternative where multiple FCUs are required across a site installation without compromising the metal clad specification.
BS 7671 Regulation 433.1 and Appendix 15 set limits on the number of spurs from a ring final circuit. Each spur may feed only one FCU (or one socket). The total number of spurs must not exceed the number of socket outlets on the ring. In practice, on a typical 32A kitchen ring, 1–2 FCUs for cooker hood and perhaps an undercounter appliance are well within limits. Always count existing spurs before adding a new one.
For multiple permanently connected appliances — for example, an extractor hood, waste disposal unit, and water softener in a fitted kitchen — consider a dedicated 20A or 32A radial circuit with individual FCUs at each appliance, supplied from the consumer unit. This keeps each fixed appliance independently protected and allows individual isolation without affecting other circuits.
An FCU fuse blows for a reason. Before fitting a replacement fuse, confirm:
If a 13A fuse blows in an FCU on a cooker hood, the hood's motor may have seized or there is a fault with the internal lamp circuit. Isolate at the FCU switch, inspect the appliance, and fit a correctly rated replacement fuse — 3A for standard hoods — before switching back on.
An FCU is the correct termination for any permanently fixed appliance taken from a ring final circuit or dedicated radial. Choose a switched (DP) FCU for all installations where local isolation is required — which is virtually every domestic application. Select white plastic for internal wall mounting, metal clad with flex outlet for cooker hoods and garages. Always fit the correct cartridge fuse rating for the appliance — 3A for hoods and small fans, 5A for larger fans and heaters, 13A for immersion and panel heaters. Confirm the spur count before adding an FCU to a ring and refer to BS 7671 Appendix 15 for ring final circuit loading limits.